Replace to Refrigeration Air Dryer----Biteman Heat Modular Desiccant Air Dryer

Model NO.: Heated BTGMXD248-A, 24.8m3/min and -40C pdp
Fluid Bed Drying Equipment Type: Multilayer Fluid Bed
Vacuum Drying Equipment Type: Continuous Vacuum
Condition: New
Flow Range: 24.8m3/Min, 875cfm
Purge Air Control: Automatically Control
Modular Units Desiccant Chamber: Replace with Factory Filled Desiccant
Pressure Dew Point: -40 Centigrade ,Optional -70c
Heat or Heatless: Heat
Trademark: BITEMAN
Transport Package: Wooden Mounting
Specification: ISO9000, ISO8573.2
Origin: Shenzhen China
BITEMAN Modular units heated desiccant air dryer

Innovative structure with patents,employs small desiccant chamber unit

1.Air flow equally and evenly pass through each desiccant chamber
2.Avoid channelling effect which more likely happens in traditional desiccant dryer
3.Small chamber allow no mandatory annul inspection
4.Molecular sieve capability is much better than Alumina and silicon desiccant in traditional dryer
5.PLC controller ,Full function touch panel control

Structure and operation

Biteman dryer have two groups of desiccant chambers,A and B ,according to flow rate,A and B shift between adsorption and regeneration

Replace to Refrigeration Air Dryer----Biteman Heat Modular Desiccant Air Dryer



Ease of replacement of desiccant chambers,it can't be more simpler comparing to exchange of desiccant,only one wrench it is done.Further more,needn't worry the desiccant density after refilling because it is filled in our factory to keep constant and stable pressure dew point,just like new dryer from factory
Replace to Refrigeration Air Dryer----Biteman Heat Modular Desiccant Air Dryer
Replace to Refrigeration Air Dryer----Biteman Heat Modular Desiccant Air Dryer

Technical data
A-series       Heatless           (-40ºC dew point)
MODEL Port (inch) Flow rate (m³/min) Dimension (mm)
@5~6bar @6~7bar @7~10bar L W H
BTGMXW065-A G2 4.8 5.8 6.5 451 240 1628
BTGMXW085- A G2 6 7.4 8.5 560 240 1628
BTGMXW106- A G2 7.4 9.1 10.6 668 240 1628
BTGMXW146- A G2 9.8 12 14.6 885 240 1628
BTGMXW165- A G2 11.6 14.2 16.5 994 240 1628
BTGMXW206- A G3 14.6 17.8 20.6 763 480 1628
BTGMXW248- A G3 16.7 20.5 24.8 794 480 1628
BTGMXW295- A G3 21.5 26.3 29.5 903 480 1628
BTGMXW336- A G3 24.1 29.5 33.6 1012 480 1628
BTGMXW385- A G3 26.8 32.8 38.5 1121 480 1628
BTGMXW425- A G3 29.7 36.4 42.5 1230 480 1628
BTGMXW465- A G4 32.7 40.1 46.5 1339 480 1628
Marks
Standard working condition:Inlet pressure 0.7MPa≤P<1.0MPa,Temperature T≤35ºC;
Working condition:Pressure 0.4MPa≤P<1.0MPa,Temperature 2ºC≤T≤40ºC;
Technical date:Pressure dew point≤-40ºC
         Purge air≤ 5%
            Pressure drop≤0.012MP
         Noise≤75dB(average);
 
A-series         Heat                (-40ºC dew point)
MODEL Port (inch) Flow rate (m³/min) Dimension (mm) Max Power
@5~6bar @6~7bar @7~10bar L W H Kw/1 Ph
BTGMXD065-A G2 4.8 5.8 6.5 451 240 1628 0.8
BTGMXD085- A G2 6 7.4 8.5 560 240 1628 1
BTGMXD106- A G2 7.4 9.1 10.6 668 240 1628 1
BTGMXD146- A G2 9.8 12 14.6 885 240 1628 1.4
BTGMXD165- A G2 11.6 14.2 16.5 994 240 1628 1.6
BTGMXD206- A G3 14.6 17.8 20.6 763 480 1628 2
BTGMXD248- A G3 16.7 20.5 24.8 794 480 1628 2.4
BTGMXD295- A G3 21.5 26.3 29.5 903 480 1628 2.8
BTGMXD336- A G3 24.1 29.5 33.6 1012 480 1628 3.2
BTGMXD385- A G3 26.8 32.8 38.5 1121 480 1628 3.6
BTGMXD425- A G3 29.7 36.4 42.5 1230 480 1628 4
BTGMXD465- A G4 32.7 40.1 46.5 1339 480 1628 4.4
Marks
Standard working condition:Inlet pressure 0.7MPa≤P<1.0MPa,Temperature T≤35ºC;
Working condition:Pressure 0.4MPa≤P<1.0MPa,Temperature 2ºC≤T≤40ºC;
Technical date:Pressure dew point≤-40ºC
         Purge air: ≤2%
         Pressure drop≤0.012MP
         Noise≤75dB(average);